The Tasso+ device is a state-of-the-art, virtually painless blood collection system designed to streamline sampling while maximizing patient comfort. Applied to the upper arm, Tasso+ uses gentle vacuum technology to draw high-quality capillary blood—eliminating the need for needles and reducing patient anxiety.

Its compact, single-use format makes it ideal for decentralized clinical trials, remote testing, and other settings where convenience and sample integrity are paramount. With minimal training required, Tasso+ enables consistent collection volumes, high patient compliance, and reliable results, all in a safe, user-friendly package.

Our Blood Draw Devices

Haiim

TAP

Tasso+

Why Use The Tasso+ Device?

The Tasso+ device offers a painless, needle-free solution for blood collection, enhancing patient comfort and compliance. Its compact, single-use design ensures hygienic, reliable sampling with consistent volumes of 300–600 µL. Ideal for decentralized trials, home testing, and clinical settings, the Tasso+ simplifies workflows, reduces anxiety, and delivers high-quality samples compatible with a broad range of assays.

Quick

& Easy

Complete the collection procedure in just 5 minutes

High
Volume

Obtain up to Collects 300-600 µL of whole blood per draw with minimal hemolysis

Versatile Tube Use

Compatible with various commercial microtubes.

Painless collection

Blood collection is done using a gentle vacuum technology.

Specifications

Sample Type: Liquid capillary blood.

Collection Volume: 300–600 µL per draw.

Design: Single-use, compact, lightweight.

Technology: Vacuum-assisted collection for reliable, high-quality samples.

Application Site: Upper arm.

Collection Time: ~5–10 minutes.

Patient Experience: Virtually painless and needle-free.

Compatibility: Supports a range of laboratory tubes (e.g., EDTA, SST).

Safety: Hygienic design prevents cross-contamination.

Use Cases: Ideal for decentralized trials, home testing, and clinical settings.

What microtubes can I use with Tasso+?

The Tasso+ device supports a wide range of assays, including:

Clinical Chemistry: Glucose, cholesterol, creatinine.

Hematology: Complete Blood Count (CBC).

Serology: Antibody detection, including SARS-CoV-2 IgG.

Endocrinology: Cortisol, thyroid hormones, estradiol, TSH.

Cardiology: Lipid panels and hsCRP.

Diabetes: HbA1c.

Liver Function: ALT, AST, bilirubin, albumin.

Kidney Function: Cystatin C, BUN, creatinine.

What Assays are Compatible with Tasso+?

The Tasso+ device supports a wide range of assays that utilize liquid capillary blood, making it suitable for various clinical and diagnostic applications. Compatible assays include:

Chemistry Panels: Basic and comprehensive metabolic panels.

Hematology: Complete blood counts (CBC) and differential analyses.

Serology: Antibody detection, including SARS-CoV-2 IgG assays.

Endocrinology: Hormone levels (e.g., cortisol, thyroid hormones, estradiol).

Cardiology: Lipid profiles (cholesterol, HDL, LDL, triglycerides) and cardiac biomarkers (e.g., hsCRP).

Diabetes Monitoring: HbA1c and glucose tests.

Liver Function Tests: ALT, AST, total bilirubin, and albumin levels.

Kidney Function: Creatinine, cystatin C, and BUN tests.

How do you determine the quality of blood drawn using Tasso+?

The quality of blood drawn using the Tasso+ device can be determined through several key assessments:

Visual Inspection: Examine the sample for signs of hemolysis (pink or red discoloration), clots, or contamination. A clear, uniformly colored sample indicates good quality.

Sample Volume: Confirm the collected volume (300–600 µL) meets the requirements for the intended assays.

Tube Handling: Ensure proper mixing of blood in tubes containing anticoagulants or additives (e.g., EDTA, SST) by following recommended procedures, such as gentle inversion.

Laboratory Testing: Perform quality control checks during laboratory analysis to assess sample integrity, including hemolysis, hematocrit levels, and analyte stability.

Consistency with Reference Values: Compare test results from Tasso+ samples with venous blood draws to verify reliability and accuracy. Studies have shown Tasso+ samples provide results comparable to venous draws for most analytes.

Adherence to Protocols: Follow the device’s instructions for use to ensure optimal performance and minimize potential errors during collection.

Our Popular Packages

  • Women’s Large Sexual Health Package

    Includes: Atopobium vaginae, Bacterial vaginosis-associated bacteria 2 (BVAB2), Candida spp, Chlamydia trachomatis, Escherichia coli O18, Gardnerella vaginalis, Herpes simplex virus, Human Papilloma virus (HPV), Lactobacillus spp, Mobiluncus spp, Mycoplasma genitalium, Mycoplasma hominis, Neisseria gonorrhoeae, Prevotella bivia, Trichomonas vaginalis, Uncultured Megasphaera spp, Ureaplasma urealyticum

    Lab results in 5 to 7 working days - No referral required

  • Gut Health Package

    Includes: Akkermansia muciniphila, Bifidobacterium bifidum, Bifidobacterium breve, Bifidobacterium genus, Bifidobacterium lactis, Bifidobacterium longum, Faecalibacterium prausnitzii, H. Pylori, Lactobacillus acidophilus, Lactobacillus gasseri, Lactobacillus genus, Lactobacillus helveticus, Lactobacillus paracasei, Lactobacillus plantarum, Lactobacillus reuteri, Lactobacillus rhamnosus, Roseburia hominis, Streptococcus thermophilus, Bacteroides fragilis, Escherichia coli, Prevotella genus, Bacteroides genus, Candida albicans, Clostridium difficile, Enterococcus faecalis, Haemophilus influenzae, Klebsiella pneumoniae, Staphylococcus aureus, Streptococcus pneumoniae, Campylobacter spp., Clostridioides difficile, Plesiomonas shigelloides, Salmonella spp., Yersinia enterocolitica, Vibrio spp., Enteropathogenic E. coli (EPEC), Shiga-like E. coli (STEC).

    Lab results in 5-7 working days. No referral required

  • Menopause Package

    Includes: FSH, LH, Oestradiol

    Lab results in 2-5 working days. No referral required

  • Women’s Fertility Package

    Includes: FSH, LH, Serum Progesterone, Prolactin

    Lab results in 2-5 working days. No referral required

Hillcrest testing locations

031 880 2150

sales@epicentre.org.za

Mon – Fri (08:30 to 16:00)

Cape Town testing locations

021 201 1658

salescpt@epicentre.org.za

Mon – Fri (08:30 to 16:00)

Johannesburg testing locations

082 065 2172

salesjhb@epicentre.org.za

Mon – Fri (08:30 to 16:00)

WhatsApp/ Emergency contact Number

072 843 7564

sales@epicentre.org.za

Mon – Fri (08:30 to 16:00)